CS4100/2100 Controllers Technical Reference
____________________________________________________________________________________________
September 2005 Page 35
Profibus Network Configuration
Before the module can be used on a Profibus-DP network some basic settings must be configured.
Baud Rate
The baud rate on a Profibus-DP network is set during configuration from the master. The module
features auto baud rate detection and the user does not have to configure the baudrate.
Supported baud rates:
1. 9.6 kbit/s
2. 19.2 kbit/s
3. 45.45 kbit/s
4. 93.75 kbit/s
5. 187.5 kbit/s
6. 500 kbit/s
7. 1.5 Mbit/s
8. 3 Mbit/s
9. 6 Mbit/s
10. 12 Mbit/s
Node Address
The switches can be used when selecting a node address in the range 00-99.
Termination
Each bus segment in a Profibus network must be terminated properly to ensure error-free operation.
If the module is used as the first or last node in a network, the termination switch has to be in ON
position. Otherwise the switch has to be in OFF position.
NOTE:
?
If an external termination connector is used, the switch must be
in the OFF position.
GSD Configuration file
A GSD file is available upon request which is applicable to this Profibus-DPV1 ANYBUS card.